左室の仮性腱索に付着した可動性血栓の3症例
Two-Dimensional Echocardiographic Findings of Mobile Thrombus Originated from the False Tendon in the Left Ventricle
中西 昌子1, 吉川 純一2, 吉田 清2, 山浦 泰子2, 穂積 健之2, 八木 登志員1, 前西 文秋1, 浜崎 利子1, 桜井 英一1
Masako NAKANISHI1, Junichi YOSHIKAWA2, Kiyoshi YOSHIDA2, Yasuko YAMAURA2, Takeshi HOZUMI2, Toshikazu YAGI1, Fumiaki MAENISHI1, Toshiko HAMASAKI1, Hidekazu SAKURAI1
1神戸市立中央市民病院 循環器検査室, 2神戸市立中央市民病院 循環器センター内科
1Department of Cardiology, Kobe General Hospital, 2Department of Cardiology, Kobe General Hospital
キーワード : Mobile thrombus, False tendon
Two-dimensional echocardiogaphy was performed in three patients with a mobile thrombus in the left ventricle. Two cases had old myocardial infarction, and the remaining dilated cardiomyopathy. Each thrombus was confirmed to have originated from the false tendon at the time of surgery.
The echocardiographic findings included; 1) a mass echo in the left ventricular cavity not attached to the ventricular wall, or detection of a false tendon around the thrombus and 2) its pendular motion.
Therefore, a thrombus attached to the false tendon should be suspected when these echocardiographic findings are observed.
Limitations in detecting false tendon and discrimating between left ventricular myxsoma and thrombi were discussed.